TM 1-1520-265-233.12.3.3 Access. Not applicable.3.12.3.4 Preparation of Part. Refer to Preparation of Part or Area for NDI, paragraph 1.4.4.3.12.3.5 Inspection Procedure. Perform fluorescent penetrant inspection. Refer to Fluorescent Penetrant Method,paragraph 1.4.7 and Table 1-5. Inspect area of concern. See Figure 3-12.3.12.3.6 Marking and Recording of Inspection Results. Mark and record inspection results as required by paragraph 1.3.3.12.4 BackupMethod. None required.3.12.5 SystemSecuring. Clean the tail rotor gearbox inner/outer split cones to remove inspection media. Refer to PostCleaning and Restoration of Part or Area After NDI, paragraph 1.4.16. The tail rotor gearbox inner/outer split conesrequire installation in accordance with the applicable technical manuals listed in Table 1-1.Figure 3-12. Tail Rotor Gearbox Inner/Outer Split Cones3-26