TM 1-1520-265-23
Change 2
5-19
5.10.3.6 Inspection Procedure.
Perform Flourescent Penetrant Inspection. Refer to the
Flourescent Penetrant Method, paragraph 1.4.7 and Table 1--5. Inspect area of concern.
5.10.3.7 Marking and Recording of Inspection Results. Mark and record inspection results as
required by paragraph 1.3.
5.10.4 Backup Method. None required.
5.10.5 System Securing. Clean the part area to remove the inspection media. Refer to the post
cleaning and restoration of part or area after NDI paragraph 1.4.16. Protective coatings shall be
applied as required. Parts or components if removed or disassembled, required installation or
reassembly in accordance with the applicable technical manuals listed in Table 1--1.
Figure 5-10. Forward Support Tube