TM 1-1520-265-236.12.3.4Preparation of Part. The part shall be thoroughly cleaned. Refer to Preparation of Part or Area for NDI,paragraph 1.4.4.6.12.3.5NDI Equipment Settings.a.Make the following initial settings on the Eddy Current Inspection Unit, NORTEC-1 9e".Frequency F1- 200 KHzF2- offHdB- 57.0VdB- 69.0Rot- 56°Probe drive- midLPF- 100HPF- 0H Pos- 80%V Pos- 20%b.Refer to Eddy Current Method, paragraph 1.4.11. Set up on test block as follows:(1)Null probe on test block.(2)Adjust phase as required to obtain horizontal lift-off.(3)Move probe over all three notches in test block. Adjust gain to obtain a three block vertical signal whenprobe is passed over 0.040-inch notch in test block. (See the standard instrument display shown in Figure1-7.)6.12.3.6 Inspection Procedure. Refer to Eddy Current Method, paragraph 1.4.11 and Figure 6-12.Figure 6-12. Pilot Collective Stick Bellcrank Support6-23