TM 1-1520-265-23
6.20.3.2 Preparation of Helicopter. The helicopter shall be prepared for safe ground maintenance. A partial inspection
for cause (visual indications, sites of mechanical damage, corrosion, etc.) may be performed on all exposed surfaces of
the installed part using applicable positions of this procedure. If required, the lateral bellcrank shall be removed in
accordance with the applicable technical manuals listed in Table 1-1.
6.20.3.3 Access. Not applicable.
6.20.3.4 Preparation of Part. The part shall be thoroughly cleaned. Refer to Preparation of Part or Area for NDI,
paragraph 1.4.4.
6.20.3. 5 NDI Equipment Settings. Refer to Magnetic Particle Method, paragraph 1.4.8.
6.20.3.6 Inspection Procedure. A magnetic field shall be applied to the part perpendicular to the orientation of possible
cracks. Positions required for this inspection are illustrated in Figure 6-20.
a.
Select AC on the AC/DC power switch.
b.
Place probe/yoke on part in position 1 as shown.
c.
Press the test switch and apply a light coat of magnetic particle media at the same time. Remove the media
momentarily before removing the current. Current should be applied for no more than five seconds.
d.
Inspect for cracks using the black light.
e.
Demagnetize before moving to the next position. Refer to paragraph 6.20.3.8.
f.
Repeat steps a. through e. for positions 2 through 5.
Figure 6-20. Lateral Bellcrank
6-40