TM 1-1520-265-23
2-34
2.16.3.5 NDI Equipment Settings.
a. Make the following initial settings on the Eddy Current Inspection Unit, NORTEC-19eII.
Frequency F1
- 1000 KHz
F2
- off
HdB
- 57.0
VdB
- 69.0
Rot
- 30_
Probe drive
- mid
LPF
- 100
HPF
- 0
H Pos
- 80%
V Pos
- 20%
b. Refer to Eddy Current Method, paragraph 1.4.11. Set up on test block as follows:
(1) .Null probe on test block.
(2) .Adjust phase as required to obtain horizontal lift-off.
(3) .Move probe over all three notches in test block. Adjust gain to obtain a three block vertical
signal when probe is passed over 0.040-inch notch in test block. (See the standard
instrument display shown in Figure 1-7.)
1.1.1.2 Inspection Procedure. Refer to Eddy Current Method, paragraph 1.4.11 and Figure 2-16.
Figure 2-16. Lower Link