TM 1-1520-265-23
Rot
- 56°
Probe drive
- mid
LPF
- 100
HPF
- 0
H Pos
-80%
V Pos
-20%
b.
Refer to Eddy Current Method, paragraph 1.4.11. Set up on test block as follows:
(1)
Null probe on test block.
(2)
Adjust phase as required to obtain horizontal lift-off.
(3)
Move probe over all three notches in test block. Adjust gain to obtain a three block vertical signal when
probe is passed over 0.040-inch notch in test block. (See the standard instrument display shown in Figure
1-7.)
3.5.3.6 Inspection Procedure. Refer to Eddy Current Method, paragraph 1.4.11 and Figure 3-5.
a.
Place probe on a good area in the inspection location and null. Adjust phase as required to obtain horizontal lift-
off.
b.
Inspect the part.
c.
Any signal similar to the notches in the test block are cause for rejection.
Figure 3-5. Tail Rotor Drive Shaft Supports
3-12