TM 1-1520-265-23Rot- 56°Probe drive- midLPF- 100HPF- 0H Pos-80%V Pos-20%b.Refer to Eddy Current Method, paragraph 1.4.11. Set up on test block as follows:(1)Null probe on test block.(2)Adjust phase as required to obtain horizontal lift-off.(3)Move probe over all three notches in test block. Adjust gain to obtain a three block vertical signal whenprobe is passed over 0.040-inch notch in test block. (See the standard instrument display shown in Figure1-7.)3.5.3.6 Inspection Procedure. Refer to Eddy Current Method, paragraph 1.4.11 and Figure 3-5.a.Place probe on a good area in the inspection location and null. Adjust phase as required to obtain horizontal lift-off.b.Inspect the part.c.Any signal similar to the notches in the test block are cause for rejection.Figure 3-5. Tail Rotor Drive Shaft Supports3-12