TM 1-1520-265-23NOTEHand-held magnetic coil may be used. Refer to paragraph 1.4.8.1.2 and Figure 1-6.3.8.3.2 Preparation of Helicopter. The helicopter shall be prepared for safe ground maintenance. A partial inspection forcause (visual indications, sites of mechanical damage, corrosion, etc.) may be performed on all exposed surfaces of theinstalled part using this procedure. If required, the fan shaft/blower assembly shall be removed in accordance with theapplicable technical manuals listed in Table 1-1.3.8.3.3 Access. Not applicable.3.8.3.4 Preparation of Part. The part shall be thoroughly cleaned. Refer to Preparation of Part or Area for NDI,paragraph 1.4.4.3.8.3.5 NDI Equipment Settings. Refer to Magnetic Particle Method, paragraph 1.4.8.3.8.3.6 Inspection Procedure. A magnetic field shall be applied to the part perpendicular to the orientation of possiblecracks. Positions required for this inspection are illustrated in Figure 3-8.Figure 3-8. Oil Cooler Axial Fan Shaft3-17