TM 1-1520-265-23
5-28
Change 2
5.16.3.6 Marking and Recording of Inspection Results. Mark and record inspection results as
required by paragraph 1.3.
5.16.4 Backup Method. None required.
5.16.5 System Securing. Clean the inspected parts to remove inspection media. Refer to Post
Cleaning and Restoration or Part or Area After NDI, paragraph 1.4.16. The rotary input assembly
requires assembly and installation in accordance with the applicable technical manuals listed in
Table 1-1.
5.17 ENGINE LOAD DEMAND CONTROL CABLE SUPPORT (PT).
5.17.1 Description (Figure 5-1, Index No. 17). The cable support is mounted on top of the
transmission and secures the engine load-demand push-pull rods.
5.17.2 Defects. Defects can occur anywhere on the surface of the support. No cracks are allowed.
5.17.3 Primary Method. Fluorescent Penetrant.
5.17.3.1 NDI Equipment and Materials. (Refer to Appendix B.) Inspection equipment is listed in
Table 1-7. AMS 2644 level 3 penetrant materials shall be selected from the approved list in Table
1-8. Parts requiring flourescent penetrant inspection shall be cleaned prior to inspection with
n--Propyl Bromide (vapor degreasing only)(Table 1--8), DS--108 (Table 1--8), Electron (Table 1--8),
Positron (Table 1--8). DS--108, Electron, Positron must be followed by an acetone (Table 1--8) rinse
or wipe: or drying until there is no visible solvent residue left on parts.
5.17.3.2 Preparation of Helicopter. The helicopter shall be prepared for safe ground maintenance.
A partial inspection for cause (visual indications, sites of mechanical damage, corrosion, etc.) may
be performed on all exposed surfaces of the installed part using this procedure. If required, the cable
support shall be removed in accordance with the applicable technical manuals listed in Table 1-1.
5.17.3.3 Access. Access is obtained through the sliding cover (Figure 1-4, items 3T-4T-2).
5.17.3.4 Preparation of Part. Refer to Preparation of Part or Area for NDI, paragraph 1.4.4.
5.17.3.5 Inspection Procedure. Perform fluorescent penetrant inspection. Refer to Fluorescent
Penetrant Method, paragraph 1.4.7 and Table 1-5. Inspect area of concern. See Figure 5-17.
5.17.3.6 Marking and Recording of Inspection Results. Mark and record inspection results as
required by paragraph 1.3.
5.17.4 Backup Method. None required.
5.17.5 System Securing. Clean the cable support to remove inspection media. Refer to Post
Cleaning and Restoration of Part or Area After NDI, paragraph 1.4.16. The cable support, if removed,
requires installation in accordance with the applicable technical manuals listed in Table 1-1.