2. Present Flight/Previous Flight Bar Display. This bar display, figure 11, allows the comparison of the
previous flight's and the present flight's vibration data on a channel-by-channel basis. The horizontal axis
displays the Test State and the vertical axis displays the vibration amplitude. The present and previous
vibration data is displayed as bars with different patterns. The screen has the capability to display up to five
Test States at one time. Use the LEFT and RIGHT arrow keys to move the screen left and right when more
than five Test States are present on the bar graph. F3 provides a tabular display of the selected vibration
data. To return to the Trend Flights display menu, press the QUIT key
Figure 11. Present Flight/Previous Flight Bar Display
k. Summary
The AVA displays provide a variety of ways to review track and vibration data. It is important to remember
that the displays available on a particular aircraft are determined by the aircraft initialization file. The displays
access the data previously stored in the database by the measuring mode. Data is stored in a generic set of
units, which can be easily converted to the desired display units. This conversion is done every time data is
displayed.