TM 1-6625-724-13&P
0022 00
0022 00-1/(0022 00-2 blank)
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS)
AVIATION VIBRATION ANALYZER
Index
General ............................................................................................................................................................................. 1
Lubrication ........................................................................................................................................................................ 1
Cleaning............................................................................................................................................................................ 1
Calibration......................................................................................................................................................................... 1
Troubleshooting................................................................................................................................................................ 1
1. GENERAL
Inspect Aviation Vibration Analyzer for missing or damaged components. Check for physical damage such as breaks,
cracks, wear, etc.
2. LUBRICATION
There are no lubrication tasks required.
3. CLEANING
Use spray cleaner (WP0066, item 6) to clean the outside surfaces of the major items. Wipe clean and dry with a soft
rag. Clean lens on the CADU and UTD with lens cleaner.
4. CALIBRATION
Calibration of the AVA will be performed by a TMDE Support Team in accordance with guidelines specified in
Calibration and Repair Requirements for the Maintenance of Army Material (TB 43-180).
5. TROUBLESHOOTING
Troubleshooting at the Aviation Unit Maintenance (AVUM) level is limited to checking for indications of normal
operation, inspecting and replacing the CADU strap, DAU Tracker Mode knob, and DAU fuse, scale adjustment, and
scale battery removal and installation.
END OF WORK PACKAGE