0025 00TM 1-6625-724-13&P0025 00-16Table 1. Error Reported on CADU Error Screen (cont.)Code #Message4115:Filter 5 Stopband Gain ACTION: (1) Power the DAU off and on (2) Wait 20 seconds, make ameasurement (3) If error persists, possible hardware failureThe 2 kHz, filter 5 has failed the filter stopband test during calibration. Power the DAU off andon, and then try to make a measurement. If the failure persists, send unit to TMDE for repair.Suspect failure of the DAU Acquisition board.4116:Filter 6 Ripple Error ACTION: (1) Power the DAU off and on (2) Wait 20 seconds, make ameasurement (3) If error persists, possible hardware failureThe 20 kHz, filter 6 has failed the filter ripple test during calibration. Power the DAU off and on,and then try to make a measurement. If the failure persists, send unit to TMDE for repair.Suspect failure of the DAU Acquisition board.4117:Filter 6 Stopband Gain ACTION: (1) Power the DAU off and on (2) Wait 20 seconds, make ameasurement (3) If error persists, possible hardware failureThe 20 kHz, filter 6 has failed the filter stopband test during calibration. Power the DAU off andon, and then try to make a measurement. If the failure persists, send unit to TMDE for repair.Suspect failure of the DAU Acquisition board.4118:Freq. Cal Consistency Error ACTION: (1) Power the DAU off and on (2) Wait 20 seconds,make a measurement (3) If error persists, possible hardware failureThe internal reference frequency test has failed on power up. Power the DAU off and on, andthen try to make a measurement. If the failure persists, send unit to TMDE for repair.4119:Freq. Test Timeout ACTION: (1) Power the DAU off and on (2) Wait 20 seconds, make ameasurement (3) If error persists, possible hardware failureThe internal frequency test has failed on power up. Power the DAU off and on, and then try tomake a measurement. If the failure persists, send unit to TMDE for repair.4120:Bad Test Module Parameter ACTION: (1) Power the DAU off and on (2) Wait 20 seconds,make a measurement4121:Bad Pipe Operation ACTION: (1) Power the DAU off and on (2) Wait 20 seconds, make ameasurement4122:Failed to Fork FFT or Aout ACTION: (1) Power the DAU off and on (2) Wait 20 seconds,make a measurement4123:Aout Module Error ACTION: (1) Power the DAU off and on (2) Wait 20 seconds, make ameasurement4124:FFT Module Error ACTION: (1) Power the DAU off and on (2) Wait 20 seconds, make ameasurement4125:Fork Error for Aout or FFT ACTION: (1) Power the DAU off and on (2) Wait 20 seconds,make a measurement4126:DAC Filter Gain Error ACTION: (1) Power the DAU off and on (2) Wait 20 seconds, make ameasurement (3) If error persists, possible hardware failureThe internal DAC filter test has failed on calibration. Power the DAU off and on, and then try tomake a measurement. If the failure persists, send unit to TMDE for repair.
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business