TM 1-6625-724-13&P0025 000025 00-19Table 1. Error Reported on CADU Error Screen (cont.)Code #Message4161:Tachometer Failure on Input 2 ACTION: (1) Verify connection (2) Verify gap or Check tapefor optical Interrupter (3) Check cableThe DAU is receiving no timing pulses from the external magnetic or optical tachometer. Verifythe following:7. Interrupter is connected to the correct channel. 8. Interrupter is gapped properly and working. 9. Optical interrupter is aimed at the reflective tape. 10. Correct cable is installed and working. Repeat measurements, as necessary. This is acommon problem caused by improper sensor connection to the DAU.4162:Tachometer Failure on CAL Source ACTION: (1) Power the DAU off and on (2) Wait 20seconds, make a measurementAn internal hardware failure. Power DAU off and on and repeat the measurements. If failurepersists, send unit to TMDE for repair. Suspect bad Acquisition board in DAU.4163:Track Sensor Fault on Channel 1 ACTION: (1) Check cable (2) Check Installation angle(ABT Installed backwards?) (3) Check lens (4) Possible Contrast Problem - Ensureunderside of blades are evenly darkened, or attempt to acquire data with UTDapproximately 10-15 degrees left or right of directly into sunVerify the following:1. The tracker is installed properly, including cable connection, installation angle, tracker arrowpointing in the direction of rotation, and the sun is not shining directly into the tracker lens.2. There is a proper light level for passive tracker or that reflective target is installed properly foractive tracker. Replace the tracker with different unit and repeat measurements.4164:Track Sensor Fault on Channel 2 ACTION: (1) Check cable (2) Check Installation angle(ABT installed backwards?) (3) Check lens (4) Verify light levelEither an incorrect number of pulses, or no pulses, are being returned from the tracker. Verifythe following:1. The UTD is installed properly, including cable connection, installation angle, tracker arrowpointing in the direction of rotation, and the sun is not shining directly into the tracker lens.2. There is a proper light level for passive tracker or that reflective target is installed properly foractive tracker. Replace the tracker with different unit and repeat measurements.4165:ABT Signal Corrupted ACTION: (1) Check cable (2) Check Installation angle (ABT Installedbackwards?) (3) Check lens (4) Verify light levelEither an incorrect number of pulses, or no pulses are being returned from the UTD. Verify thefollowing:1. The UTD is installed properly, including cable connection, installation angle, tracker arrowpointing in the direction of rotation, and the sun is not shining directly into the tracker lens.2. There is a proper light level for passive tracker or that reflective target is installed properly foractive tracker. Replace the tracker with different unit and repeat measurements.4166:Blade Apparently Too Close ACTION: (1) Verify tracker Installation (2) Verify SETUP -Check and Reload aircraft script fileSystem measures the blade velocity too slowly. Verify the UTD is installed properly and thesetup file agrees with the aircraft configuration. Repeat measurements, as necessary.4167:ABT Apparently Looking Beyond Blade Tip ACTION: (1) Verify tracker Installation (2)Verify SETUP - Check and Reload aircraft script fileVerify the proper installation of the UTD. Repeat measurements as necessary.
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business