TM 1-6625-724-13&P
0039 00
0039 00-3
(e) Put PWA (16) in place and inspect lens surface from operator's side of CADU.
(f) If lint or smudges are still present, repeat steps (a) through (e).
12. Install four lock screw assemblies (14).
13. Install six standoffs (11), six flat washers (12), and ground lug (13).
14. Install three washers (10), three lock washers (9), and three screws (8) on PWA edge adjacent to battery
pack.
15. Connect battery pack cable connector (6) to J6 on PWA (16).
16. Connect cable connector (7) to J4 on PWA (16).
17. Inspect O-ring (29). If replacement is needed, use Permabond 910 (item 3, WP0066 00) to seal O-ring.
18. Place bottom plate (4) in place in top case (5).
19. Install nine washers (3), nine lock washers (2), and nine screws (1).