TM 1-6625-724-13&P
0007 00
0007 00-1
TURN ON/OFF PROCEDURES
AVIATION VIBRATION ANALYZER
CAUTION
The operator must exit DPL prior to performing a
system reboot of the AVA to prevent the possible
loss or corruption of the internal database data.
Figures
Figure 1. Start-Up Selection Menu............................................................................................................................. 1
Figure 2. DPL Booting Window.................................................................................................................................. 2
Figure 3. Main Menu .................................................................................................................................................. 2
a. Power On Procedure
The CADU is powered from the DAU, the 12 Vdc battery charger, or by its own internal rechargeable battery
pack. The internal battery pack is being charged anytime the CADU is connected to external power by the 12
Vdc battery charger or DAU. The CADU can be operated while charging. Power is distributed to the CADU
when the DAU power switch is activated. To operate the CADU with or without external power, press the ON
key. The CADU will operate eight hours with a fully charged battery, depending on lamp usage. If the CADU
does not respond it may be necessary to reboot it, see step b.
b. Reboot and Start-Up Selection Menu
Note
The recommended procedure for rebooting the CADU is a
soft reboot, see step 1. If the CADU is locked up a hard
reboot is necessary, see step 2.
1. A soft reboot of the CADU is accomplished by simultaneously pressing the DO and QUIT keys.
2. A hard reboot of the CADU is accomplished by first pressing the OFF key. While pressing and holding
the HELP key press the ON key.
For either case the following message will display after a few seconds:
CADU System Bootstrap V3.1
Please Wait...
When the above message goes away, the Start-Up Selection Menu will appear (refer to figure 1).
*******************************************
***
RADS-AT
***
*******************************************
Please select an option:
1: Proceed with normal operation
2: Set up for host communication
use this option with the
RADSCOM diskette.
3. Load aircraft setup flies from
the credit card
4: Modem setup
5: Help menu
Select (1, 2, 3, 4, or 5):
Figure 1. Start-Up Selection Menu