0025 00TM 1-6625-724-13&P0025 00-30Table 1. Error Reported on CADU Error Screen (cont.)Code #Message32567:No Diagnostics Setup For This Flight Plan Of The AircraftAn attempt was made to run diagnostics on an aircraft that has not been configured fordiagnostics. Verify the aircraft type under test has diagnostics configured in the aircraft setupfile.32568:No Measurements Exist for Current FlightThere are no acquisition setups in the aircraft configuration file for the current Flight Plan. Verifycorrect aircraft configuration file.32668:DAU Failure Without Error Code ACTION: (1) Power the DAU off and on (2) Wait 20seconds, make a measurementInternal software fault. Power the DAU off and on, and then repeat measurements. If the faultpersists, send unit to TMDE for repair.32678:Tracker Not Connected ACTION: (1) Check cable (2) Check installation angle (ABTinstalled backwards?)(3) Check lens (4) Verify light levelNone or incorrect number of pulses are being returned from the tracker. Verify the following:1. The UTD is installed properly, including cable connection, installation angle, tracker arrowpointing the direction of rotation, and the sun is not shining directly into the tracker lens.2. There is a proper light level for passive tracker or that reflective target is installed properly foractive tracker. Replace the tracker with a different unit and repeat measurements.32698:Attempt to Read Illegal ChannelSend unit to TMDE for repair.32707:Restore FailedData could not be restored from the credit card. See previous error message for a betterindication of the failure.32708:Backup FailedA backup to either PC or credit card has failed. This is usually a secondary message. See theprevious message for a better indication of the fault. Possible causes are: improper connectionto a PC, no credit card installed, write protect on the credit card, and credit card failure.32714:Printer Type Not SetA printer type has not been selected. Enter the MANAGER Menu and select a printer type.32715:Can Not Set Printer TypeSend unit to TMDE for repair.32716:Can Not Disable PrintingSend unit to TMDE for repair.32717:Can Not Enable PrintingSend unit to TMDE for repair.32718:Printer System Incorrectly SetupSend unit to TMDE for repair.32728:DAU Not Ready, Wait 10 Seconds and Retry Measurement. ACTION: Verify that the DAU'spower switch Is onThe CADU and DAU are not talking. Turn the DAU off and on, and then try to make ameasurement. If this does not work, reboot the CADU. Verify that the CADU-to-DAU cable isproperly installed. If it is still inoperable, send unit to TMDE for repair.
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business