0025 00
TM 1-6625-724-13&P
0025 00-30
Table 1. Error Reported on CADU Error Screen (cont.)
Code #
Message
32567:
No Diagnostics Setup For This Flight Plan Of The Aircraft
An attempt was made to run diagnostics on an aircraft that has not been configured for
diagnostics. Verify the aircraft type under test has diagnostics configured in the aircraft setup
file.
32568:
No Measurements Exist for Current Flight
There are no acquisition setups in the aircraft configuration file for the current Flight Plan. Verify
correct aircraft configuration file.
32668:
DAU Failure Without Error Code ACTION: (1) Power the DAU off and on (2) Wait 20
seconds, make a measurement
Internal software fault. Power the DAU off and on, and then repeat measurements. If the fault
persists, send unit to TMDE for repair.
32678:
Tracker Not Connected ACTION: (1) Check cable (2) Check installation angle (ABT
installed backwards?)(3) Check lens (4) Verify light level
None or incorrect number of pulses are being returned from the tracker. Verify the following:
1. The UTD is installed properly, including cable connection, installation angle, tracker arrow
pointing the direction of rotation, and the sun is not shining directly into the tracker lens.
2. There is a proper light level for passive tracker or that reflective target is installed properly for
active tracker. Replace the tracker with a different unit and repeat measurements.
32698:
Attempt to Read Illegal Channel
Send unit to TMDE for repair.
32707:
Restore Failed
Data could not be restored from the credit card. See previous error message for a better
indication of the failure.
32708:
Backup Failed
A backup to either PC or credit card has failed. This is usually a secondary message. See the
previous message for a better indication of the fault. Possible causes are: improper connection
to a PC, no credit card installed, write protect on the credit card, and credit card failure.
32714:
Printer Type Not Set
A printer type has not been selected. Enter the MANAGER Menu and select a printer type.
32715:
Can Not Set Printer Type
Send unit to TMDE for repair.
32716:
Can Not Disable Printing
Send unit to TMDE for repair.
32717:
Can Not Enable Printing
Send unit to TMDE for repair.
32718:
Printer System Incorrectly Setup
Send unit to TMDE for repair.
32728:
DAU Not Ready, Wait 10 Seconds and Retry Measurement. ACTION: Verify that the DAU's
power switch Is on
The CADU and DAU are not talking. Turn the DAU off and on, and then try to make a
measurement. If this does not work, reboot the CADU. Verify that the CADU-to-DAU cable is
properly installed. If it is still inoperable, send unit to TMDE for repair.