TM 1-6625-724-13&P0025 000025 00-29Table 1. Error Reported on CADU Error Screen (cont.)Code #Message32367:KERMIT Lost Connection, Please Check Cable and PC, and Try AgainThe CADU to PC cable is not connected properly. Verify the proper cable is being used and thecable is plugged into the correct PC port. Repeat the backup to PC operation.32368:KERMIT Failed to Establish Connection, Please Check Cable and PC, and Try AgainThe CADU to PC cable is not connected properly. Verify the proper cable is being used and thecable is plugged into the correct PC port. Repeat the backup to PC operation.32453:Unknown Module Failure - Please Report ACTION: (1) Repeat key sequence (2) RebootCADUInternal software failure. Reboot the CADU. If the failure persists, send unit to TMDE for repair.32454:CADU Still Setting Up The DAU, Please Wait 10 Seconds And Retry Measurement ACTION:(1) Check CADU to DAU cable (2) Check that DAU's power switch Is on (3) Reboot DAUThe DAU, which is currently connected to the CADU, was not started connected to the currentCADU. Turn the DAU power off and on, and then repeat the measurement.32455:Monitor Power Not Running, Try Reboot of CADU ACTION: (1) Retry measurement (2)Check CADU to DAU cable (3) Check that DAU's power switch Is on (4) Reboot CADUThe process that starts the DAU is not running properly in the CADU. Reboot the CADU andrepeat the measurement. If the failure persists, send unit to TMDE for repair.32456:Non-module in DAU download directory, CADU wrongly configured32457:DAU Test Error, Possible Hardware Failure ACTION: (1) Power the DAU off and on (2) Wait20 seconds, make a measurementThe power on self-test has not returned properly. Turn the DAU off and on and repeat themeasurement. If the failure persists, send unit to TMDE for repair.32458:Failed to Set EEPROM date in DAU, Possible Hardware Failure ACTION: (1) Power the DAUoff and on (2) Wait 20 seconds, make a measurementThe date has not been properly set in the DAU EEPROM. Turn DAU off and on, and then repeatthe measurement. If the failure persists, send unit to TMDE for repair.32468:Insufficient Space to Store Results ACTION: (1) Backup and delete some flight data (2)(not for the Credit Card) After deleting data - run the Manager Menu's compress option32563:Too Many Adjustments, Best N Can't Optimize More Than 30. Use EDIT Adjustables toadd constraints32564:Invalid Point Range (Low- point % -high-point %) in setup. This limit check Is notpossible. ACTION: Check setup defined In aircraft script file AND/OR Reload aircraftscript file32565:Impossible to Calculate Corrections - Please Edit the Adjustments to Add ConstraintsNot enough data has been collected to run the diagnostics without going to the diagnostics editorand eliminating some adjustments. Either collect more data or go to diagnostics editor.32566:Failed to Load Enough DataNot enough data is available to run the diagnostics. Acquire the required data, as specified inthe Flight Plan.
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business