Table 1. Error Reported on CADU Error Screen (cont.)
Code #
Message
32367:
KERMIT Lost Connection, Please Check Cable and PC, and Try Again
The CADU to PC cable is not connected properly. Verify the proper cable is being used and the
cable is plugged into the correct PC port. Repeat the backup to PC operation.
32368:
KERMIT Failed to Establish Connection, Please Check Cable and PC, and Try Again
The CADU to PC cable is not connected properly. Verify the proper cable is being used and the
cable is plugged into the correct PC port. Repeat the backup to PC operation.
32453:
Unknown Module Failure - Please Report ACTION: (1) Repeat key sequence (2) Reboot
CADU
Internal software failure. Reboot the CADU. If the failure persists, send unit to TMDE for repair.
32454:
CADU Still Setting Up The DAU, Please Wait 10 Seconds And Retry Measurement ACTION:
(1) Check CADU to DAU cable (2) Check that DAU's power switch Is on (3) Reboot DAU
The DAU, which is currently connected to the CADU, was not started connected to the current
CADU. Turn the DAU power off and on, and then repeat the measurement.
32455:
Monitor Power Not Running, Try Reboot of CADU ACTION: (1) Retry measurement (2)
Check CADU to DAU cable (3) Check that DAU's power switch Is on (4) Reboot CADU
The process that starts the DAU is not running properly in the CADU. Reboot the CADU and
repeat the measurement. If the failure persists, send unit to TMDE for repair.
32456:
Non-module in DAU download directory, CADU wrongly configured
32457:
DAU Test Error, Possible Hardware Failure ACTION: (1) Power the DAU off and on (2) Wait
20 seconds, make a measurement
The power on self-test has not returned properly. Turn the DAU off and on and repeat the
measurement. If the failure persists, send unit to TMDE for repair.
32458:
Failed to Set EEPROM date in DAU, Possible Hardware Failure ACTION: (1) Power the DAU
off and on (2) Wait 20 seconds, make a measurement
The date has not been properly set in the DAU EEPROM. Turn DAU off and on, and then repeat
the measurement. If the failure persists, send unit to TMDE for repair.
32468:
Insufficient Space to Store Results ACTION: (1) Backup and delete some flight data (2)
(not for the Credit Card) After deleting data - run the Manager Menu's compress option
32563:
Too Many Adjustments, Best N Can't Optimize More Than 30. Use EDIT Adjustables to
add constraints
32564:
Invalid Point Range (Low- point % -high-point %) in setup. This limit check Is not
possible. ACTION: Check setup defined In aircraft script file AND/OR Reload aircraft
script file
32565:
Impossible to Calculate Corrections - Please Edit the Adjustments to Add Constraints
Not enough data has been collected to run the diagnostics without going to the diagnostics editor
and eliminating some adjustments. Either collect more data or go to diagnostics editor.
32566:
Failed to Load Enough Data
Not enough data is available to run the diagnostics. Acquire the required data, as specified in
the Flight Plan.