TM 1-6625-724-13&P0025 000025 00-25Table 1. Error Reported on CADU Error Screen (cont.)Code #Message16390:Sensor Fault on Internal Channel 4 ACTION: (1) Check cable (2) Check accelerometer -find channel associated with position number above, In script file16391:Bad Accelerometer Type ACTION: (1) Retry measurement (2) Verify Setup – Check andReload aircraft script fileThe accelerometer type specified in the aircraft setup file is incorrect. Verify accelerometer typein the aircraft setup file.16392:Illegal Channel Number ACTION: (1) Retry measurement (2) Verify Setup - Check andReload aircraft script fileThe accelerometer channel specified in the aircraft setup file is incorrect. Verify the channelsetups in the aircraft setup file.16393:ACQ Min Limit > Max Limit ACTION: (1) Power the DAU off and on (2) Wait 20 seconds,make a measurement16394:Bad Power of 2 for Strobe Adjust ACTION: (1) Power the DAU off and on (2) Wait 20seconds, make a measurement16395:Gain - Illegal Number of Samples ACTION: (1) Power the DAU off and on (2) Wait 20seconds, make a measurement16396:Cal - Illegal Number of Samples ACTION: (1) Power the DAU off and on (2) Wait 20seconds, make a measurement16397:Illegal Oversampling Factor ACTION: (1) Power the DAU off and on (2) Wait 20 seconds,make a measurement16398:Illegal Filter Selected ACTION: (1) Power the DAU off and on (2) Wait 20 seconds, make ameasurement16399:Flash Rate Too Big or Zero ACTION: (1) Power the DAU off and on (2) Wait 20 seconds,make a measurement16400:Illegal Gain Setting ACTION: (1) Power the DAU off and on (2) Wait 20 seconds, make ameasurement16401:Could Not Start Acquisition ACTION: (1) Power the DAU off and on (2) Wait 20 seconds,make a measurement16402:Illegal Physical Channel ACTION: (1) Retry measurement (2) Verify Setup – Check andReload aircraft script fileThe physical channel in the aircraft setup file is specified incorrectly. Verify the aircraft setup file.16403:Illegal Sample Rate ACTION: (1) Power the DAU off and on (2) Wait 20 seconds, make ameasurement16404:Illegal Rev Count ACTION: (1) Power the DAU off and on (2) Wait 20 seconds, make ameasurement
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business