TM 1-6625-724-13&P
0053 00
0053 00-1
UTD BULB SOCKET
REMOVAL AND INSTALLATION
CAUTION
This assembly contains parts sensitive to damage
by Electrostatic Discharge (ESD).
Use precautionary ESD procedures when touching,
removing or inserting. Use static-free material to
wrap the assembly for shipment or storage.
Index
Removal............................................................................................................................................................................ 1
Installation......................................................................................................................................................................... 2
Initial Setup:
Personnel Required:
TMDE Support Specialist
Tools and Equipment:
Tool Kit, Electricians
Parts/Materials:
Bulb Socket PN 28131300 or H989, Thread-lock adhesive, Teflon thread tape,
Silicone Adhesive
Equipment Condition:
Place UTD on workbench with ESD capabilities.
CAUTION
This assembly contains parts sensitive to damage
by Electrostatic Discharge (ESD).
Use precautionary ESD procedures when touching,
removing or inserting. Use static-free material to
wrap the assembly for shipment or storage.
a. REMOVAL:
1. Remove eight screws (1), eight flat washers (2) eight hex nuts (3), and eight flat washers (4), from base (5).
2. Using a sharp knife, break seal and remove base (5) with O ring (6) from top body (7).
3. De-solder two connecting wires (8) from terminals (9).
4. Remove two screws (10), two split washers (11), and two flat washers (12) from lower section of PWA (13).