0051 00
TM 1-6625-724-13&P
0051 00-2
5. Remove three screws (14), three lock washers (15), three flat washers (16) and three nylon spacers (17)
from top section of PWA (13) allowing removal of PWA (13).
6. Disconnect cable connector P1 (18) from bottom side of the PWA (13) at J1 (19).
7. Remove two diode caps (20) from holes.
8. The PWA is now available for replacement.
b. INSTALLATION:
1. Apply thread-lock adhesive on threaded hardware.
2. Connect cable connector P1 (18) to bottom side of the PWA (13) at J1 (19).
3. Install two diode caps (20) into two holes.
4. Slowly position the PWA (13) aligning the two sensors on the bottom side of the PWA (13) into two holes
(20) in the top body (7).
5. Install three screws (14), three lock washers (15), three flat washers (16), and three nylon spacers (17).
6. Install two screws (10), two split lock washers (11), and two flat washers (12).
7. Solder two connector wires (8) onto two terminals (9).
8. Verify O-ring (6) is in the base (5).
9. Apply silicone adhesive (item 2, WP0066 00) to mating surfaces of base (5) and body (7).
10. Install base (5) using eight hex nuts (3), eight flat washers (4), eight screws (1), and eight flat washers (2).
Figure 1. UTD PWA Removal and Installation
END OF WORK PACKAGE