0025 00TM 1-6625-724-13&P0025 00-24Table 1. Error Reported on CADU Error Screen (cont.)Code #Message4249:Accelerometer Saturation on Accelerometer Channel 11 ACTION: (1) Verify Setup (SetupStatus In Manager Menu) (2) Change accelerometer Type (3) Relocate accelerometer4250:Accelerometer Saturation on Accelerometer Channel 12 ACTION: (1) Verify Setup (SetupStatus In Manager Menu) (2) Change accelerometer Type (3) Relocate accelerometer4251:Accelerometer Saturation on Accelerometer Channel 13 ACTION: (1) Verify Setup (SetupStatus In Manager Menu) (2) Change accelerometer Type (3) Relocate accelerometer4252:Accelerometer Saturation on Accelerometer Channel 14 ACTION: (1) Verify Setup (SetupStatus In Manager Menu) (2) Change accelerometer Type (3) Relocate accelerometer8193:Reception Not Acknowledged ACTION: (1) Retry measurement (2) Check CADU to DAUcable (3) Check that DAU's power switch Is on (4) Reboot CADU8194:Spkt missed a Recvack Event ACTION: (1) Retry measurement (2) Check CADU to DAUcable (3) Check that DAU's power switch is on (4) Reboot CADU8195:Spkt Missed a Xmitack Event ACTION: (1) Retry measurement (2) Check CADU to DAUcable (3) Check that DAU's power switch is on (4) Reboot CADU8196:Illegal Communication Channel Number ACTION: (1) Reboot CADU (2) Repeat keysequence (3) If error reoccurs, Please report error to RADS-AT manufacturer (instead ofreporting error to manufacturer, report error to AVSCOM).8197:Data Transmission Error ACTION: (1) Retry measurement (2) Check CADU to DAU cable(3) Check that DAU's power switch Is on (4) Reboot CADU8198:Data Reception Error ACTION: (1) Retry measurement (2) Check CADU to DAU cable (3)Check that DAU's power switch Is on (4) Reboot CADU8199:Communications Failure ACTION: (1) Retry measurement (2) Check CADU to DAU cable(3) Check that DAU's power switch is on (4) Reboot CADU16385: Measurement AbortedThe measurement has been aborted due to user initiated abort or other failure. This message isusually a reported after another error message.16386:Too Many Samples Out-of-Range ACTION: (1) Power the DAU off and on (2) Wait 20seconds, make a measurementThe DAU has detected too many samples that saturate the internal sampling circuit. Repeat themeasurement. This error is caused by amplitude ranges changing drastically during acquisition.May be caused by extreme turbulence.16387:Sensor Fault on Internal Channel 1 ACTION: (1) Check cable (2) Check accelerometer -find channel associated with position number above, In script file16388:Sensor Fault on Internal Channel 2 ACTION: (1) Check cable (2) Check accelerometer -find channel associated with position number above, In script file16389:Sensor Fault on Internal Channel 3 ACTION: (1) Check cable (2) Check accelerometer -find channel associated with position number above, In script file
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business